14 MINUTES 29 SECONDS · GEORGE NARRATION

Room 84: mains water to boiler

Follow the incoming supply, test pressure and flow, investigate a weak hot tap and distinguish the boiler’s sealed heating circuit.

Published

Room 84 — Mains Water to Boiler. The complete narrated training-room walkthrough, including stop-valve operation, flow testing and the separate sealed heating circuit.

Watch the complete 14-minute 29-second Room 84 walkthrough with George narration. Follow the incoming supply, operate the stop valve, test pressure and flow, investigate a weak hot tap and distinguish the sealed heating circuit. English captions and all eleven chapters are available.

The film demonstrates an interactive training room. On-screen repairs, pressure settings, booster changes and hand-pump strokes are examples within that room, not universal installation or servicing instructions.

Jump to a chapter

Choose a chapter to jump to that point. Press Play if the film is paused.

  1. 0:00Room 84Link to chapter
  2. 0:45Follow the supplyLink to chapter
  3. 1:58The stop valveLink to chapter
  4. 3:20Regulating the pressureLink to chapter
  5. 4:19A weak incoming mainLink to chapter
  6. 5:04Using the flow cupLink to chapter
  7. 6:43Measure at the tapLink to chapter
  8. 8:00Diagnose a weak hot tapLink to chapter
  9. 11:21The sealed heating circuitLink to chapter
  10. 13:21Read the whole installationLink to chapter
  11. 13:49Explore Boiler Help in HxARLink to chapter
Read the complete spoken transcript

0:00 · Room 84

Welcome to Room 84. Mains water to boiler.

Here on basement level 1, we'll follow the water from the incoming main, through the installation, and out of the taps.

Here's a puzzle. The boiler gauge reads 1.5 bar, yet the hot tap barely runs. Which pressure would you check first? Keep that question in mind as we explore the room.

There are two good places to take a reading. The instruments beside the sink tell us what's being delivered at the tap. The blue sleeve beneath the boiler shows what's reaching its cold inlet.

0:45 · Follow the supply

Start at floor level. The blue pipe is the incoming cold main. Follow it upwards to the brass stop valve. Water for both the basin and the sink passes through here.

The copper pipework branches around the walls. One branch supplies cold water directly to an outlet. Another feeds the combi, where water for the hot taps is heated as it passes through.

At the sink, the small temperature marker selects hot or cold. The projecting lever opens the mixer. Watch the end of the spout as the lever moves.

Under the sink, two small service valves isolate the mixer feeds. The white waste pipe has a P-trap. Water held in the bend forms a seal.

Leave the mixer running on cold and close its cold service valve. Watch the stream stop. Reopen the same valve and the stream returns. We've isolated just this feed while keeping the main supply available.

1:58 · The stop valve

Back at the brass stop valve, use a finger or an Apple Pencil to turn either end of the handle. Clockwise closes it. Anticlockwise opens it. The circular guide tracks the opening.

Watch the stream while the handle turns. As the opening gets smaller, less water gets through. Open it again and the stream picks up.

A short tap on the valve starts the gland leak exercise. Look closely where the spindle enters the valve body. That's where the droplets appear.

The spanner fits over the gland nut. Turn it gently clockwise in the exercise and follow the repair indicator. When the leak stops, the spanner disappears.

Hold the stop valve for a closer look. The entire headwork unscrews and comes away. Watch the parts separate along the spindle, then come back together in the same order.

The cutaway reveals the seat inside the body. Lifting the washer away from the seat opens a route for the water.

3:20 · Regulating the pressure

Immediately above the stop valve is the pressure reducing valve. Tap it to see the screwdriver and two figures. One is the setting. The other is the outlet pressure.

Both taps are shut. Watch the setting go from 5 bar down to 3.5. The outlet can retain 5 bar until a tap releases the trapped pressure.

Open a tap and water leaves the downstream pipe. Close it again and read the outlet pressure. This time it settles at 3.5 bar, matching the setting.

Now draw water at both outlets. They share the incoming supply. Opening the second tap changes what's available to the first, even though its handle hasn't moved.

4:19 · A weak incoming main

Tap the blue pipe at floor level to change the incoming pressure. As we lower it, the room changes the example installation. The reducer gives way to a straight pipe, and then to an inline booster.

The switched socket supplies power to the booster. With the taps shut, it's on standby. Watch the lights when we give it a demand.

Open the mixer and compare the flow with the socket switched off, then on again. The inlet setting stays the same. This lets us see the difference the powered booster makes to delivery.

5:04 · Using the flow cup

Back at the sink, there are three instruments. From left to right, a measuring jug, a flow cup, and a digital pressure and flow tester.

The flow cup is the narrow one in the middle. Look for the black graduations marked in litres per minute.

Tap the cup itself. It leaves the shelf and stands directly under the spout, ready to catch the stream.

Open the mixer lever and watch the blue water rise. Look below the cup as well. Water is already draining through the opening in its base while fresh water enters at the top.

Give the level time to settle. When water is leaving the cup as quickly as it's entering, the level holds steady. Here it's between the 6 and 9 marks. The on-screen reading is about 7 L/min.

Leave the mixer running and turn the brass stop valve down to a quarter open. Watch how far the level falls. The on-screen reading drops to about 1.7 L/min.

Close the mixer and the rest of the water drains away. Tap the cup once more. You can see it back in its place, between the jug and the digital tester.

6:43 · Measure at the tap

The stop valve is fully open again. Tap the digital tester to fit it to the spout. The mixer closes during fitting. Reopen the lever and use the tester's blue discharge handle.

With the discharge open, water can pass through the tester. Read the upper number for the pressure while the water is moving. The lower number tells you how many litres pass in a minute.

Here we have 2.4 bar at the tester and about 6.2 L/min. Keep the discharge open while the instrument settles, then watch what happens when we close it.

The mixer stays open to the instrument, but the discharge is shut. With no other tap running, the flow falls to zero and the pressure recovers to 3 bar. That's our static reading.

The jug gives us another way to measure flow. Divide the litres collected by the time in seconds, then multiply by sixty. We'll use 30 seconds for each test.

8:00 · Diagnose a weak hot tap

Let's return to that weak hot tap. Touch the blue sleeve under the combi, then choose the weak tap test. The mixer is set to hot and the sealed heating gauge reads 1.5 bar.

Both taps are shut. The cold inlet to the boiler reads 3 bar and the flow through the boiler is zero. That's our starting point. What happens under demand?

Open the hot mixer. With the stop valve only a quarter open, the inlet pressure falls to about 0.14 bar. Only 1.7 L/min is passing through the boiler.

Now put the jug under the hot tap and let the timer run. We're measuring how much water the tap actually delivers in 30 seconds. Watch the blue level against the graduations.

Even with the mixer open, the water level rises slowly. At this rate, will the jug reach the 1 litre mark before the time runs out?

0.87 L. That's about 1.7 L/min. Close the mixer and tap the jug to return it.

For a fair comparison, keep the incoming supply at 5 bar. Change just one thing. Turn the brass stop valve anticlockwise until the guide shows fully open.

Under the same hot tap demand, the boiler inlet now reads 2.24 bar. Flow is up to about 7 L/min.

Follow the blue marker. It traces the cold main from the stop valve to the inlet beneath the boiler.

Now follow the red marker from the domestic hot outlet. It runs round the corner to the mixer. This is the route the water takes during our hot tap test.

Same jug, same hot tap, same 30 seconds. Look how quickly the level reaches the first graduation. Last time, the whole sample came to less than 1 litre.

30 seconds is half a minute. Once the timer stops, doubling the volume in the jug gives the delivery in litres per minute. What result would you expect this time?

3.49 L in 30 seconds. That's about 7 L/min, roughly four times our first result. The sealed heating gauge has stayed at 1.5 bar throughout.

Close the hot outlet and run just the cold basin tap. It still draws from the main, but the domestic flow through the boiler reads zero.

11:21 · The sealed heating circuit

That leaves the gauge on the front of the boiler. It measures pressure in the sealed heating circuit. Follow the silver filling loop. When opened, it lets water from the cold main into the heating return.

In this example the supply is only 0.5 bar. Open the silver loop and the heating pressure rises until it reaches that same half bar. There's no further pressure difference to drive water in, and this boiler still shows a low pressure block.

Look on the floor in front of the radiator. This is a reservoir hand pump. It holds a separate supply of water that we can pump into the sealed heating circuit.

Tap the tank to connect it. The mains filling valve closes, the silver loop is stowed, and the black hose connects the hand pump to the heating return.

One stroke of the lever takes this training boiler from 0.5 bar to 0.6 bar. That's enough to clear its low pressure interlock. There's still more pumping to do.

Keep an eye on the pump dial as the lever moves. In this exercise, each stroke adds up to 0.1 bar. We're bringing the cold heating circuit up to its target of 1.5 bar.

Tap the tank again to disconnect the hand pump. The black hose comes away and the silver filling loop returns with its valve closed.

Check the boiler gauge once more. The sealed heating circuit is holding 1.5 bar after the hand pump has been disconnected.

13:21 · Read the whole installation

Three readings help tell the story. What's the inlet pressure with the taps closed? What pressure remains when a tap is running? And how much water actually arrives at the outlet in a minute?

In our weak tap test, opening the stop valve restored hot water flow. The front gauge was telling us about a separate circuit all along.

13:49 · Explore Boiler Help in HxAR

Download the HxAR app and try Room 84 yourself. Change the pressure and experiment with the tools.

Find a boiler, open Boiler Help, and choose a tutorial. You can repeat the exercises at your own pace.

Subscribe to our YouTube channels to follow the next boiler tutorials as they're released.

We're also preparing a mains water stop valve lesson for the EPHG website. The page address is on screen. Thanks for watching.